Combi Boiler No Hot Water? 7 Things to Check First
Combi boiler no hot water? It’s one of the most common boiler problems, especially in winter, and the cause is often something simple you can check yourself in a few minutes. Below, our Gas Safe engineers explain what to check first, what the error code on your boiler is telling you, and which faults need an engineer.
Combi boiler no hot water: 7 things to check first
1. Is there an error code on the display?
Most modern combi boilers show a code when something goes wrong, usually a letter and a number such as F28, EA or L2. Write it down, along with your boiler’s make and model (it’s on the front or underneath). Then look the code up in your boiler’s manual or on the manufacturer’s website. The code tells you, and us, where to start.
2. Do you have heating but no hot water?
Turn on a hot tap and check whether your radiators are warm. If the heating works but the hot water doesn’t, the boiler itself is lighting, so the fault is usually in the parts that switch it over to hot water (see the common faults below). If you have no heating and no hot water, start with checks 3 to 6.
3. Check the boiler pressure
Look at the pressure gauge on the front of the boiler. With the boiler off, it should read about 1 to 1.5 bar. If it’s below 1 bar, many boilers lock out and stop working. Our guide shows you how to top up your boiler pressure safely.
4. Is the condensate pipe frozen?
In freezing weather, the small plastic pipe that runs from your boiler to a drain outside can freeze. The boiler then shuts down, often with a gurgling noise and an error code. Here’s how to thaw a frozen condensate pipe safely.
5. Is the gas on?
Check your gas hob lights. If you’re on a prepayment meter, check you have credit. If the hob doesn’t light either, the problem is your gas supply, not the boiler.
6. Reset the boiler
Press the reset button once and give the boiler a few minutes to restart. If the same error comes back, don’t keep resetting it. A repeated lockout means a fault that needs looking at.
7. Check the hot water settings
Make sure the hot water dial or setting hasn’t been turned down or switched off, and that the boiler isn’t in a holiday or eco mode that limits hot water. It sounds obvious, but it happens more often than you’d think.
Smell gas? Leave the property and call the National Gas Emergency number on 0800 111 999 straight away.
Still no hot water?
A Gas Safe engineer can look at your boiler and its error code with you on a WhatsApp video call, and often fix it there and then. £25 + VAT (£30 total), and if it needs a visit, your £30 comes off the repair.
Book a £30 video fix →The most common causes of no hot water from a combi
If the simple checks don’t fix it, these are the parts that most often cause a combi boiler to stop giving hot water. Every one of them needs a Gas Safe engineer to diagnose and replace.
Diverter valve
The diverter valve switches the boiler between heating your radiators and heating your tap water. If it sticks, you may get heating but no hot water, or hot water that’s only lukewarm.
Flow sensor
The flow sensor tells the boiler that you’ve turned on a hot tap. If it fails or gets clogged, the boiler doesn’t know to start heating the water, so it stays cold.
Plate heat exchanger
This small heat exchanger heats your tap water. Over time it can get blocked with scale or sludge, which can make hot water lukewarm, go hot and cold, or stop altogether.
Temperature sensor (thermistor)
Sensors tell the boiler how hot the water is. A faulty one can make the boiler shut off too early or not fire at all for hot water.
Ignition or fan faults
If the boiler isn’t lighting at all, the fault may be with the ignition, the gas valve or the fan. You’ll usually have no heating either, and the display will normally show an error code.
Circuit board (PCB)
The circuit board controls everything in the boiler. It’s less common than the faults above, but a failed board can stop hot water and heating completely.
Can I fix it myself?
You can safely do the checks above: read the error code, top up the pressure, thaw a frozen condensate pipe, check the gas and reset the boiler once. Anything inside the boiler casing must be done by a Gas Safe registered engineer. Never remove the casing yourself.
Combi boiler no hot water FAQs
Why do I have heating but no hot water?
Because the boiler is lighting, the fault is usually in the parts that switch it over to hot water, most often the diverter valve or the flow sensor. Both need a Gas Safe engineer.
Why is my hot water only lukewarm?
Lukewarm water often points to a sticking diverter valve, a partly blocked plate heat exchanger, or the hot water temperature being set too low. Check the setting first.
How much does it cost to fix?
It depends on the fault and the part. A reset or a pressure top-up costs nothing, while a replacement part costs more. Book a video call or send us the error code and your boiler’s make and model, and we’ll tell you what we think it is before we visit.
Is it worth repairing an old combi boiler?
Usually, if it’s under about 10 years old and has been serviced. If it’s older and breaking down often, a new boiler may be better value, and we can often fit one the next day.